Perinsul SL
FOAMGLAS®
PERINSUL® SL is an innovative
product developed by PITTSBURGH CORNING to eliminate thermal bridges
at joints within wall constructions. FOAMGLAS®
PERINSUL® SL blocks, manufactured
from FOAMGLAS®, are designed
to form an effective insulated joint between vertical wall insulation
and horizontal floor or roof insulation. Possessing all the thermal
properties for which FOAMGLAS®
is well proven, together with the exceptionally high compressive
strength of FOAMGLAS®, cold
bridging is eliminated and structural integrity maintained.
Applications:
FOAMGLAS®
PERINSUL®
SL has a compressive strength of 3000 kN/m2
and, when a safety factor of 3 is used, it has a load bearing capacity
of 1 N/mm2
without compression or deformation. It can therefore be installed
at the base of structural walls in the following situations:
- inner walls (block or brick)
- outer walls (block or brick)
- parapets
- access points
- support areas for roof trusses
 |
| This thermal image shows the major cold bridge and high thermal
loss at the junction between the floor slab and wall construction. |
| Junction of External Wall / Ground Floor Basement |
 |
| Optimised thermal bridge free construction.
The PERINSUL® SL
block is fitted under the external wall to stop the cold
bridge. |
| a / b |
e
[W/mK] |
i,o
i,u
[W/mK] |
fo / fu
[-] |
| 100 / 60 |
0,020 |
0,034
0,097 |
0,931
0,882 |
| 120 / 80 |
0,062 |
0,032
0,121 |
0,922
0,899 |
| 140 / 100 |
0,092 |
0,031
0,138 |
0,929
0,909 |
|
| |
| Junction Basement / Ground Floor |
 |
| Optimised thermal bridge free construction.
The PERINSUL® SL
block insulates between the wall and ground floor slab. |
| a / c |
e
[W/mK] |
i
[W/mK] |
f
[-] |
b = 175
100 / 60
120 / 80
140 / 100 |
-0,055
-0,038
-0,026 |
0,118
0,113
0,110 |
0,834
0,847
0,855 |
b = 240
100 / 60
120 / 80
140 / 100 |
-0,067
-0,043
-0,028 |
0,127
0,124
0,122 |
0,835
0,847
0,854 |
|
- Values:
The calculation is based on the building elements; this gives a
design value of the -value
(heat loss coefficient for thermal bridge (W/mK) with reference
to the length of the element).
Using FOAMGLAS®, -values
can be achieved of zero or even negative values. The calculation
follows the European regulations for thermal energy saving, taking
into consideration the heat loss by thermal bridges in an optimal
way.
FOAMGLAS® for Installation
| 1. |
For optimum speed of installation
on the job site it is recommended that FOAMGLAS®
PERINSUL® SL blocks are
placed adjacent to the area of work. |
4. |
PERINSUL SL blocks are laid with
closely butted end joints without mortar. Soft mortar is used
above and below the block, using the same technique as for bricks. |
| 2. |
A bed of mortar for the first course
of insulation blocks is applied. |
5. |
Fully waterproof, PERINSUL®
SL forms a capillary break reducing the risk of moisture progressing
up the wall. |
| 3. |
The height position of the PERINSUL®
SL block is adjusted. |
6. |
Building blocks are installed on
top of the row of PERINSUL®
SL as the wall construction progresses. |
|