Perinsul SL

FOAMGLAS® PERINSUL® SL is an innovative product developed by PITTSBURGH CORNING to eliminate thermal bridges at joints within wall constructions. FOAMGLAS® PERINSUL® SL blocks, manufactured from FOAMGLAS®, are designed to form an effective insulated joint between vertical wall insulation and horizontal floor or roof insulation. Possessing all the thermal properties for which FOAMGLAS® is well proven, together with the exceptionally high compressive strength of FOAMGLAS®, cold bridging is eliminated and structural integrity maintained.

Applications:
FOAMGLAS
® PERINSUL® SL has a compressive strength of 3000 kN/m2 and, when a safety factor of 3 is used, it has a load bearing capacity of 1 N/mm2 without compression or deformation. It can therefore be installed at the base of structural walls in the following situations:

  • inner walls (block or brick)
  • outer walls (block or brick)
  • parapets
  • access points
  • support areas for roof trusses
This thermal image shows the major cold bridge and high thermal loss at the junction between the floor slab and wall construction.

Junction of External Wall / Ground Floor Basement
Optimised thermal bridge free construction. The PERINSUL® SL block is fitted under the external wall to stop the cold bridge.
a / b e
[W/m•K]
i,o i,u
[W/m•K]
fo / fu
[-]
100 / 60 0,020 0,034
0,097
0,931
0,882
120 / 80 0,062 0,032
0,121
0,922
0,899
140 / 100 0,092 0,031
0,138
0,929
0,909
 
Junction Basement / Ground Floor
Optimised thermal bridge free construction. The PERINSUL® SL block insulates between the wall and ground floor slab.
a / c e
[W/m•K]
i
[W/m•K]
f
[-]
b = 175
100 / 60
120 / 80
140 / 100

-0,055
-0,038
-0,026

0,118
0,113
0,110

0,834
0,847
0,855
b = 240
100 / 60
120 / 80
140 / 100

-0,067
-0,043
-0,028

0,127
0,124
0,122

0,835
0,847
0,854

- Values:
The calculation is based on the building elements; this gives a design value of the -value (heat loss coefficient for thermal bridge (W/mK) with reference to the length of the element).

Using FOAMGLAS®, -values can be achieved of zero or even negative values. The calculation follows the European regulations for thermal energy saving, taking into consideration the heat loss by thermal bridges in an optimal way.

FOAMGLAS® for Installation

1. For optimum speed of installation on the job site it is recommended that FOAMGLAS® PERINSUL® SL blocks are placed adjacent to the area of work. 4. PERINSUL SL blocks are laid with closely butted end joints without mortar. Soft mortar is used above and below the block, using the same technique as for bricks.
2. A bed of mortar for the first course of insulation blocks is applied. 5. Fully waterproof, PERINSUL® SL forms a capillary break reducing the risk of moisture progressing up the wall.
3. The height position of the PERINSUL® SL block is adjusted. 6. Building blocks are installed on top of the row of PERINSUL® SL as the wall construction progresses.

Request Literature